Frequently Asked Questions

You have questions? We have answers. The most commonly asked questions regarding our Spherisator Series are answered here. If your question is not found or answered here, please contact BRACE technical service at info@brace.de.

Drip Casting

No pressure in the feed tanks

  • Check the correct connection of the quick disconnect coupler, release the fitting and reinsert it until an audible clicking is heard
  • Check the compressed air supply
  • Check the connection cable between control cabinet and drip casting unit

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

No feed flow

  • Check the correct connection of the quick disconnect coupler, release the fitting and reinsert it until an audible clicking is heard
  • Check the compressed air supply
  • Check the connection cable between control cabinet and drip casting unit
  • Increase the pressure in the feed tanks
  • Check if the liquid in the feed tanks is too viscose

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

No flow through the nozzle

  • Clean nozzle
  • Replace nozzle with larger nozzle
  • Reduce viscosity

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Only large droplets are formed

  • Increase the pressure until a straight flow appears
  • Clean the nozzle
  • Increase nozzle diameter

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

The droplets are all of different size

  • Change the frequency
  • Change the amplitude
  • Change the pressure
  • Check function of Vibrator

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Between the droplet very small droplets are formed

  • Decrease the pressure
  • Increase the frequency

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

In air the droplets are nice, but in the reaction bath I get flat spheres

  • Reduce the distance to the reaction bath
  • Decrease the surface tension of the reaction bath (e.g. with alcohol or detergent)

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

In the air the droplets are nice, but in the reaction bath I get “hats” and “triangles”. I cannot reduce the distance to the bath anymore

  • Reduce the amplitude
  • Use a larger nozzle
  • Reduce the flow rate

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

In air the droplets are nice, but in the reaction bath I get flat spheres

  • Reduce the distance to the reaction bath
  • Decrease the surface tension of the reaction bath (e.g. with alcohol or detergent)

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

In the air the droplets are nice, but in the reaction bath I get “hats” and “triangles”. I cannot reduce the distance to the bath anymore

  • Reduce the amplitude
  • Use a larger nozzle
  • Reduce the flow rate

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Electronics

Frequency Generator shows ** Error: 151 ** - Illegal Command

An error message ** Error: 151 ** - Illegal Command is shown in the frequency generator display:

Error 151 displayed in frequency generator

  • The error can happed sometimes if frequency +/- or amplitude +/- is pressed very quickly and very often
  • The error can be removed by pressing the "Enter" key on the keypad of the frequency generator. Simultanously, the red light under "REM" will go off. With the next change in frequency/amplitude, the red light under "REM" will turn on again.
  • If the error is shows very often, please check the connection cable between frequency generator and PLC inside the electronic cabinet (detach, reattach and fix screws)
  • Replace the RS232 connection cable between PLC and frequency generator
  • Check parameter settings of frequency generator in the user menu (baud rate and protocol). it should be 9600 bit/s and RTS/CTS.
  • If this does not help, please contact BRACE technical service for replacement of the frequency generator.

 

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Vibrator is not working

  • Check if the PLC is turned on
  • Press “Start/Stop” at the PLC
  • Check the connection cable between control cabinet and drip casting unit
  • Check the cable inside the vibrator housing

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Stroboscope not working

  • Check if the power plug is correct connected (in the plug at the back of the drip casting unit)
  • Check if the trigger cable is correctly connected
  • If possible try a different 230V socket
  • Remove the trigger cable and set the strobe frequency to 50 Hz, if it works now, replace trigger cable
  • Replace bulb

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Circulation pump not working

  • Check if the rotor is blocked
  • Inverse the direction to see if the motor is blocked
  • Check the power connection (socket in the control cabinet)

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Heating chamber is not working

  • Check cable connection
  • Check power supply
  • Check fuses

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Heating chamber is not getting warm

  • Check the fuses inside the control cabinet (ultra quick melting fuses), replace fuses
  • Replace the heating rod

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Heating chamber fan is not working

  • Turn on the fan with the regulation on the left side

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Heating chamber fan is making loud noises

  • Check if the fan is damaged
  • Check if anything blocks the fan
  • Check if the fan is mounted correctly
  • Replace fan

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

PLC display empty

  • Turn on main switch
  • Check power cable
  • Check power supply
  • Check fuses in the control cabinet
  • Check internal connections of the PLC

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Frequency generator display empty

  • Check if PLC is working
  • Check power connection
  • Check power cable inside the control cabinet
  • Check fuses inside the control cabinet
  • Check fuses of the frequency generator

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Nozzles and Nozzle Plates

How do I clean the nozzle(s)?

Nozzle cleaning shall be done with

  • flushing the nozzles with DI-water
  • an ultrasonic bath in water (5-10 min, for nozzle diameter <150µm 2-5 min)
  • drying with compressed air

If that does not clean the nozzle (visual control):

  • using air pressure from the nozzle tip, do not apply mechanical force to the tip, use a piece of tube if necessary
  • ultra sonic bath with hot/boiling water
  • acidic bath (depending on nozzle material)

Last update on 24-02-20252025 by Dr. Thorsten Brandau.

Microsphere Technology

Can a general encapsulated formulation for bioencapsulation be done, that unifies very different properties? E.g. enteric but also stable in liquid carrier for a long time?

Microencapsulation is an optimization of an active for a specific application. The more specific the application, the less optimized such a formulation will be for a different application. That means, to put it simply, “Encapsulation is easy. Will it work in your system? That is the difficult part.”

An enteric system needs an encapsulation that is resistant to low pH and dissolves in basic pH. For bioencapsulation, most systems are dried to avoid growth of bacteria in the storage time in the shelf live. So an enteric system can be provided by a suitable selction of matrix/shell materials and if necessary an additional coating.

The storage in a liquid, like a soft drink, can usually be done with similar formulations, as soft drinks have low pH around 4-4.5. However, if the matrix of shell is a usual hydrocolloid, it will take up water and swell. Such a formulation is more complex but can still be adapted to the microbes in question and is likely to perform as desired.

If the liquid is not a soft drink, but a dairy product like milk, or neutral water, it gets more difficult. Not impossible but more difficult.

All these formulations need development, and testing. As each active and especially each microbe tend to perform very different, it is always necessary to test and validate the formulation every time.

Typically, such complex encapsulations are rather done by core-shell encapsulation, than by matrix encapsulation. Often, additional coatings are necessary, making the formulation more complex.

If a specific shelf live is sought for, formulation developments take not less than the desired storage time, usually twice or more. A shelf life compliance can only be done by a real time shelf life test. There are some accellerated test conditions, that will give some knowledge about the stability, however, only a real time test is suitable. Usually such developments demand more iterations in formulation development that other encapsulated formulations.

The typical storage conditions for encapsulated probiotics also determine the difficulty. If -20°C or below is a typical storage conditions, most probiotics are very stable in the encapsulated form. At 4-8°C it will be possible for the majority. If temperatures of 20°C or more are mandatory, especially of non-dried storage conditions, the number of microbes that are suitable for encapsulation gets a lot smaller.

Generally it is important to understand what are the “must have”s are in an application. The “nice to have”s can still be added if the mandatory properties are solved.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

Do TOFFON control systems support data recording and audit trails?

The control system provides comprehensive process-data storage and recording, and supports audit-trail functionality to meet compliance-related recordkeeping requirements for food and biological products in overseas markets.

The equipment is supported by a complete 3Q qualification and FAT/SAT documentation system to support auditability. Our in-house-developed SCADA/WinCC supervisory system meets the requirements for comprehensive process-data storage and recording. It also supports the extension and application of the OPC UA communication protocol.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

How energy-efficient are TOFFON freeze dryers?

The optimized refrigeration system delivers excellent energy performance while maintaining the required low-temperature water-vapor capture capability. Processing BRACE microspheres can further shorten the drying cycle and reduce energy consumption per unit of product.

Approximate energy consumption per kilogram of water removed: 2.5 kW·h/kg.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

Can TOFFON freeze dryers be integrated with a BRACE microsphere production line?

Yes. We can jointly coordinate the process conditions so that frozen microspheres produced by BRACE are transferred into the freeze dryer and the complete production line operates in coordination.

We offer complete solutions for handling and transferring frozen microspheres automatically into the drying area.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

Are BRACE microspheres prone to breakage or sticking during freeze-drying?

Microspheres are unlikely to break when suitable freeze-drying parameters are used. The particles are individually formed spheres and are thoroughly pre-frozen. Appropriate control of the temperature ramp and vacuum profile can effectively prevent them from sticking together.

The freeze-drying process allows control of both heating and cooling rates.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

What CIP/SIP and validation capabilities do TOFFON freeze dryers offer?

Clean-in-place (CIP) and sterilization-in-place (SIP) functions are available as options, together with a complete validation documentation package, supporting hygienic production and GMP-related validation requirements for food and probiotic products.

CIP: Internal spray manifolds and spray balls can be fitted as options.

SIP: Equipment configured for SIP is classified as pressure-vessel equipment. Vaporized hydrogen peroxide (VHP) sterilization is also available as a more economical alternative.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

How uniform is the temperature of the heating shelves in TOFFON freeze dryers?

The shelves provide uniform temperature control with low temperature variation across each shelf. This ensures consistent heating of the material in the trays, reduces differences in microsphere dryness between locations and supports batch consistency.

Measurements recorded at multiple locations on different shelves show an overall temperature variation within 2 °C.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

How accurately can TOFFON freeze dryers control vacuum?

The vacuum system provides stable control and precise adjustment, maintaining the constant vacuum conditions required for freeze-drying food and biological products.

Vacuum control methods include:
1. Controlled gas admission into the vacuum system.

2. Capacity control using multiple vacuum-pump sets.

3. Variable-frequency control of vacuum pumps.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

What ice-condenser temperatures can TOFFON freeze dryers achieve?

TOFFON freeze dryers provide stable low-temperature control of the ice condenser. The refrigeration system can be selected to suit the material and process requirements, providing the low temperatures and water-vapor capture capacity required for microsphere freeze-drying.

Single-stage refrigeration system: ice-condenser temperature of −35 to −50 °C.

Two-stage refrigeration system: ice-condenser temperature of −50 to −65 °C.

Cascade refrigeration system: ice-condenser temperature of −60 to −80 °C.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

Why do BRACE microspheres dry faster and save more than 50% in energy compared with conventional tray freeze-drying of liquid materials?

1. The microspheres are already pre-cooled and frozen during formation, eliminating the prolonged pre-freezing stage inside the freeze dryer.

2. The separate spherical particles leave open spaces between them, providing unobstructed sublimation pathways and substantially improving sublimation efficiency.

3. The uniform, controllable ice-crystal structure reduces resistance to heat and mass transfer, shortening the overall drying cycle and delivering significant energy savings.

4. The uniform size of the particles allow a sharp reduction of the drying time to the optimum value

5. The spherical form and the packing of the spheres in the trays allow an 720°-sublimation of water by increasing the surface area

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

For liquid coffee concentrate loaded directly onto trays, the usual recommendation is 10–15 kg/m², with a liquid layer thickness of 10–15 mm. For solid microspheres produced using the BRACE process, voids remain between the particles. The loading capacity can reach 10–15 kg/m² and, under suitable conditions, up to 20–30 kg/m². A higher bed load is also possible.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

How does the BRACE process achieve multilayer encapsulation and particle formation?

The BRACE processes can use annular gap nozzles to produce core-shell, double shell or even triple shell particles in one process. These coaxial nozzles extrude a two (or three or four) layered stream of liquids (Microcapsules), which is then broken up identical as with a single material (Microspheres).

For such Microcapsules, the suitable number of feed materials and a suitable nozzle plate are needed, while the rest of the unit is the same as for a single feed stream.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

BRACE’s nozzle plate uses many nozzles to achieve high throughput. When all nozzles discharge simultaneously, how is consistent particle size maintained? How do surface tension and vibration influence the formation?

The vibrating nozzle technology combines surface tension with fixed-frequency vibration to produce uniform droplet breakup (“Laminar Flow Rayleigh Breakup with Vibrating Nozzles”).

When a liquid is extruded in a laminar flow from an orifice, the surface tension forms a wave in the surface of the resulting liquid cylinder. The cylinder breaks up into similar sized droplets.

As in the natural – vibration free – break up the droplet size is not optimal, a larger variation including very small droplets (“Satellites”) are formed.

By vibrating the liquid directly (or indirectly via the nozzle/nozzle plate) in resonance to the wave on the surface, a very narrow size distribution of droplets are formed, the satellites vanish. The viscosity supports the forming of a droplet in the process and to stabilize the shape of the droplet.

Due to the technical setup, the vibration and flow is at any position of a high precision nozzle plate identical, even if the plate contains millions of nozzles. Therefore the droplet creation is identical over the nozzle place, creating only a very narrow size distribution of particles.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

What are the functions of the stroboscope and camera fitted to the two BRACE systems?

Droplets emerge from the vibrating nozzle too rapidly for their formation to be observed directly with the naked eye. A stroboscopic lamp creates an apparent freeze-frame effect, making the fast-moving droplets appear stationary. Additionally a magnification can be used for small droplets. This allows operators to check the stability of droplet formation and breakup in real time, assess nozzle vibration and adjust process parameters.

The accompanying camera captures these images for local viewing and remote video monitoring, supporting on-site commissioning and remote technical assistance.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

Does the BRACE Binder system require refrigeration?

The need for a specific solidification system depends on the material to be processed. If the material are thermogelling typically a Fusion process with a cooling tower offers the best processing. In case of hydrocolloids like Alginate, Pectin, Agar or Gelatine, polymers or sol-gel processing, usually a Binder process setup is the better choice. In the Binder process direct contact thermogelling is also used.

Ionic crosslinking for materials as Alginate, Sols or some polymers are typically performed in a Binder process, UV curing of polymers in a Fusion type setup.

It depends on the material and application, which solidification system offers the best performance.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

Which cooling options are available for the BRACE Fusion process? How does liquid nitrogen cooling differ from immersion in a liquid nitrogen bath?

The droplets generated in the process have to be solidified. Different materials need different types of solidification.

In the Binder process materials as gelatine or agar typically us a cold oil in direct contact.

For materials that are solidifed in gas (Fusion process) such as melts, instant products, some probiotics etc., there are two options. The technically simpler one is to use nitrogen gas as inert gas made out of liquid nitrogen. This offers a technically simple and highly efficient solution. Additionally the cooling gas is very dry and non-oxidative, which is especially for flavors, essential oils or anaerobic bacteria an advantage.

Alternatively and where liquid nitrogen is not an option, a compressor cooling can be used. In that case, the gas (mainly air, but nitrogen is also an option) is circulated via filter and dehumidifier. It is a technically more complex setup with high installation and maintenance costs, which offers less flexibility.

Other processes use a dripping directly into liquid nitrogen. Even if this is possible at high capacities with a Binder process type setup, the quality of such particles are inferior due to the Leidenfrost effect, which leads to a lot of coagulation. Many of the process advantages of narrow size distribution are cancelled out by this kind of processes. It is therefore not recommended.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

How to select the particle diameter in the process? Can it be fine tuned without changing the machine?

The droplet size area is selected by the nozzle diameter. With the process parameters the droplet size is fine tuned. As in the process first of all a droplet is generated, that is about 2 times the diameter of the nozzle, the final product diameter might vary if the collected and solidified particles are dried and then shrink. Typical shrink rates on drying are about 20-50%. For ceramics, sintering can produce further shrinking of ca. 20-30%.

For practical terms that means that to produce a 1 mm droplet, a 500 µm nozzle is used. With the same nozzle droplets of 800µm and 1200µm are usually feasible. Depending on the properties of the materials this range might be bigger or smaller.

Such a 1mm droplet can shrink on drying to e.g. 700µm. In case of a ceramic, it may finally have a size of 500µm after sintering.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

What particle diameter range can the BRACE process produce?

BRACE vibrating nozzle technology can produce particle diameters ranging from 15 μm to 15,000 μm (15 mm).

Particle size can be customized within this range while maintaining good sphericity and a narrow particle size distribution. The actual range that can be produced consistently depends on material viscosity, solids content, nozzle selection and process parameters. Particle sizes outside the stated range require preliminary laboratory trials.

It has however to keep in mind, that very small or very large particles will influence production and investment costs for units. Selection of a particle diameter in the “comfort zone” of ca. 200-2000µm offers typically the most economical products.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

How does the complete BRACE process control microbial contamination, and how is the processing environment managed?

BRACE equipment and processes can be configured with various options for use in the field of food/feed, cosmetic and pharma. This includes WIP (Wash-In-Place), CIP (Clean-In-Place) and SIP (Sterilize-In-Place) capabilities, closed systems, even pressurized isolated units.

Equipment: Machine parts in contact with the product are typically made from stainless steel (AISI 316) and a typical surface roughness of Ra<1.2, Ra<0.8 or even Ra<0.6 are available, depending on the application and scope. Other materials used in contact with the product are usually Glass or Plastic suitable for Food applications. Sealmaterial is usually FDA certified, unless technical reasons need something else (e.g. silver or carbon seals). Close systems, WIP, CIP, SIP can be configured, even over or underpressure isolation or glove boxes can be offered.
Processing environment: For desktop of laboratory units the operation in a suitable proper or cleanroom is recommended, especially for GMP purposes. For pilot and production units, full housing, glove boxes or mobile cleanrooms can be offered. Production units can be offered as closed systems and also with housing for over- or underpressure to prevent contamination of the material or the environement.
Feed pretreatment: As many raw materials for encapsulation are only available in food grade, BRACE offers inline sterilization for the raw materials, but also post production pasteurisation for food products as bubble tea.
Closed feed design: Production units can be offered as closed line systems to reduce contact with ambient air. Air showers, UV desinfection system or even fully isolated operation can be realized to remove the risk of contamination.
Process monitoring: Although monitoring does to avoid contamination, production units and as option smaller units offer sampling ports to confirm the quality and free-of-contamination for the material at checkpoints.
The hygienic level depends on the size and configuration of the unit. All units can be optionally designed for highest hygienic level, depending on the application and customer needs. For laboratory equipment and use e.g. in the probiotic nutrient field, desinfection and controlled rooms are often sufficient to product products.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

What is the maximum solids content that the BRACE process can handle when processing suspensions?

Solid contents for polymers are naturally 100%, but when it comes to suspension, emulsions or solutions, the solid content influences the viscosity. It is better to look at the viscosity, instead of the solid content. BRACE has successfully processed mixtures with up to ca. 83% solid content.

The processes are very versatile and typically work with high solid content solutions/suspensions/emulsions. The achievable droplet/particle diameter depends on the viscosity, which is influenced by the solid content.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

What is the difference between “concentration” and “solid content”?

The definition varies depending on the industry and the form of liquid. While in suspensions “solid content” typically referrs to the weight% of the insoluble material, it can also mean the amount of materials (in weight%) except the solvent (usually water).

In instant applications, this referrs to the residue when all water is removed, often also gives as BRIX.

In solution “concentration” includes only the material dissolved in the solvent and not the solid or liquid part. Here a “concentration” can differ from the “solid content”, if a liquid is both, a solution and a supsension at the same time, but also Emulsions can have both.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

What is the maximum feed viscosity that the BRACE process can handle?

Viscosity is on of the key parameters of the process. As the viscosity needs to be in the allowed area of the Reynolds-Ohnsorg diagram for laminar flow, the combination of nozzle diameter/droplet size, surface tension, density and viscosity determines the possibiity to use the BRACE process. As those parameters are connected and influence each other, it is not easy to answer, however, a hard limit of 10.000 cP is widely accepted, with a comfort zone below 1000 cP. With the use of rehology modifiers, temperature, booster or other optimizations, it can be said that most materials short of high molecular weight polymers can be processes.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.

BRACE’s presentation materials and website state that maximum throughput can exceed 100 tonnes per hour. Which projects have been implemented at this scale, and what are ceramic microspheres used for?

BRACE equipment can achieve industrial-scale production on the order of 100 tonnes per hour. Several benchmark projects have been implemented:

1. Agricultural microsphere project in South America

Agricultural and fertilizer applications need large amounts of nitrogen sources for plant growth. Microspheres offer advantages in transport, delivery and release for use in the field.

2. Microspheres for downwell/oilfield application (North America, Eurasia)

Ceramic microspheres are used as proppants in oil, gas, shale oil and shale gas extraction. During hydraulic fracturing, the ceramic proppants are pumped into fractures in the formation together with the fracturing fluid. After pumping stops, the microspheres hold the rock fractures open and prevent them from closing, allowing oil and gas to continue flowing from the formation and improving hydrocarbon recovery.

Last update on 19-10-20262026 by Dr. Thorsten Brandau.